Sensor Issues

During the development of the weather station, it was found that the temperature sensor mounted internally was causing the station to report very high temperatures compared to the "real" ambient temperature reported by the NWS (20-40 degrees higher). The leading theory for this issue was that the BECC building was cooking the sensor and artificially raising the temperature of the sensor.

The solution to this problem was to mount the sensor outside the box, in a small, well-ventilated enclosure, which was implemented.

image

New 3d-printed case manufactured out of PETG enclosing the weather station's temperature sensor

The Temperature was Wrong... again?

After mounting the new sensor, it was found that the temperature was still ten degrees higher than what the National Weather Service, and other sources were reporting. Again, the theory was still that the BECC was cooking the sensor. To verify this, a thermocouple measurement board was used to detect the ambient air temperature around the building and... it was the same as what the sensor was reporting.

image

Measuring the ambient air temperature with a thermocouple using a Playing with Fusion FDQ-30001 board

It was clear that the issue was simply the weather station was too close to the BECC, and that the glass and concrete was radiating too much heat to get an accurate measurement for ambient air temperature.

What was Done Wrong

It all started when we mounted the weather station: the location was not conducive to accurately measuring ambient temperature. The front of a large glass building blasts the air in front where the weather station is, heating it to well above ambient temperature.

After some research, and finding an article about measuring ambient air temperature, and one of the major issues listed was: "don't put ambient air measurement equipment near large buildings or pavement." With the current weather station location in front of the BECC, we were doing exactly that.

The New Test

These issues arose a question: is campus truly that hot, or just in front of the BECC. To find the answer to this, the weather station group went around campus measuring a couple points and comparing that data to the National Weather Service reported data. Unfortunately, the day chosen to perform these measurements was bitterly cold, and the team only got about four locations measured.

Test was conducted on 2025-02-13, at around 1:00pm

This data can be visualized with the GPS data with the Test Html.

Our Test Data

Time Temp (C) Pressure (kPa)
13:19 10.7 (C) 100.9 kPa
13:22 7.8 (C) 100.9 kPa
13:26 5.5 (C) 100.9 kPa
13:31 2 (C) 101.0 kPa

NWS Data

Time Temp (C) Pressure (kPa)
13:54 -8.0 (C) --
12:54 -8.8 (C) --